精品国模一区二区三区,一区二区三区无码精油的作用,中文字幕亚洲欧美日韩在线不卡 ,日韩人妻一区二区三区蜜桃视频

您好,歡迎來(lái)到給覽網(wǎng)!手機(jī)版|供應(yīng)歸檔|本站服務(wù)|添加收藏|幫助中心
 當(dāng)前位置: 首頁(yè) » 資料 » 其它資料

Mouse IgG ELISA Kit

Word文檔
  • 文件類型:Word文檔
  • 文件大?。?.2M
  • 更新日期:2015-09-30 14:11
  • 瀏覽次數(shù):676   下載次數(shù):3899
進(jìn)入下載
詳細(xì)介紹
 

 

Mouse IgG ELISA Kit

For the quantitative in vitro determination of Mouse Immunoglobulin G concentrations in

 serum - plasma - celiac fluid - tissue homogenate - body fluid

 

 

 

 

 

FOR LABORATORY RESEARCH USE ONLY.

NOT FOR USE IN DIAGNOSTIC PROCEDURES.

 

 

This package insert must be read in its entirety before using this product.

 

ELISA

ENZYME linkED IMMUNOSORBENT ASSAY

 

 

 

INTENDED USE AND TEST PRINCIPLE

This IgG ELISA kit is intended Laboratory for Research use only and is not for use in diagnostic or therapeutic procedures. The Stop Solution changes the color from blue to yellow and the intensity of the color is measured at 450 nm using a spectrophotometer. In order to measure the concentration of IgG in the sample, this IgG ELISA Kit includes a set of calibration standards. The calibration standards are assayed at the same time as the samples and allow the operator to produce a standard curve of Optical Density versus IgG concentration. The concentration of IgG in the samples is then determined by comparing the O.D. of the samples to the standard curve.

 

SAMPLE COLLECTION AND STORAGES

Serum - Use a serum separator tube and allow samples to clot for 2 hours at room temperature or overnight at 4℃ before centrifugation for 20 minutes at approximately 2000×g. Remove serum and assay immediately or aliquot and store samples at -20℃. Avoid repeated freeze-thaw cycles

Plasma - Collect plasma using heparin as an anticoagulant. Centrifuge samples for 30 minutes at 2000×g at 2-8℃ within 30 minutes of collection. Store samples at -20℃. Avoid repeated freeze-thaw cycles.

Cell culture supernates, tissue homogenate and other biological fluids - Remove particulates by centrifugation and assay immediately or aliquot and store samples at -20℃. Avoid repeated freeze-thaw cycles.

Note:  The samples shoule be centrifugated dequately and no hemolysis or granule was allowed.

 

MATERIALS REQUIRED BUT NOT SUPPLIED

1.  37 ℃ incubator

2.  Standard microplate reader capable of measuring absorbance at 450 nm

3.  Precision pipettes, disposable pipette tips and Absorbent paper

4.  Distilled or deionized water

 

REAGENTS PROVIDED

All reagents provided are stored at 2-8°C. Refer to the expiration date on the label.

 

Name

96 determinations

48 determinations

Microelisa stripplate

12*8strips

12*4strips

Standard6 vial

0.5ml/vial

0.5ml/vial

Sample diluent

6.0ml

3.0ml

HRP-Conjugate reagent

10.0ml

5.0ml

20 Wash solution

25ml

15ml

Chromogen Solution A

6.0ml

3.0ml

Chromogen Solution B

6.0ml

3.0ml

Stop Solution

6.0ml

3.0ml

Closure plate membrane

2

2

User manual

1

1

Sealed bags

1

1

Note:

1.  Standard concentration was followed by: 4020、10、5、2.51.25 μg/mL.

2.  If samples generate values higher than the highest standard, please dilute the samples with Sample Diluent and repeat the assay.

 

PRECAUTIONS

1.         Do not substitute reagents from one kit lot to another. Standard, conjugate and microtiter plates are matched for optimal performance. Use only the reagents supplied by manufacturer.

2.         Allow kit reagents and materials to reach room temperature (20-25°C) before use. Do not use water baths to thaw samples or reagents.

3.         Do not use kit components beyond their expiration date.

4.         Use only deionized or distilled water to dilute reagents.

5.         Do not remove microtiter plate from the storage bag until needed. Unused strips should be stored at 2-8°C in their pouch with the desiccant provided.

6.         Use fresh disposable pipette tips for each transfer to avoid contamination.

7.         Do not mix acid and sodium hypochlorite solutions.

8.         Serum and plasma should be handled as potentially hazardous and capable of transmitting disease. Disposable gloves must be worn during the assay procedure, since no known test method can offer complete assurance that products derived from Rat blood will not transmit infectious agents. Therefore, all blood derivatives should be considered potentially infectious and good laboratory practices should be followed.

9.         All samples should be disposed of in a manner that will inactivate viruses.

10.     Liquid Waste: Add sodium hypochlorite to a final concentration of 1.0%. The waste should be allowed to stand for a minimum of 30 minutes to inactivate the viruses before disposal.

11.     Substrate Solution is easily contaminated. If bluish prior to use, do not use.

12.     Substrate B contain 20% acetone, keep this reagent away from sources of heat or flame.

13.     Remove all kit reagents from refrigerator and allow them to reach room temperature ( 20-25°C).

 

REAGENT PREPARATION AND STORAGE

Wash Solution (1X) - Dilute 1 volume of Wash solution (20) with 19 volumes of deionized or distilled water. Wash Solution is stable for 1 month at 2-8°C.

 

ASSAY PROCEDURE

1.  Prepare all reagents before starting assay procedure. It is recommended that all Standards and Samples be added in duplicate to the Microelisa Stripplate.

2.  Add 20μl of Standard or Sample to the appropriate wells. Blank well doesn’t add anyting.

3.  Add 10l of HRP-conjugate reagent to standard wells and sample wells except the blank well, cover with an adhesive strip and incubate for 60 minutes at 37°C.

4.  Wash the Microtiter Plate 4 times.

Manual Washing - Remove incubation mixture by aspirating contents of the plate into a sink or proper waste container. Using a squirt bottle, fill each well completely with Wash Solution (1X), then aspirate contents of the plate into a sink or proper waste container. Repeat this procedure for a total of four times. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears. Note: Hold the sides of the plate frame firmly when washing the plate to assure that all strips remain securely in frame.

Automated Washing - Aspirate all wells, then wash plates four times using Wash Buffer (1X). Always adjust your washer to aspirate as much liquid as possible and set fill volume at 350μL/well/wash. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears.

5.  Add chromogen solution A 50μl and chromogen solution B 50μl to each well. Gently mix and incubate for 15 minutes at 37°C. Protect from light.

6.  Add 50μl Stop Solution to each well. The color in the wells should change from blue to yellow. If the color in the wells is green or the color change does not appear uniform, gently tap the plate to ensure thorough mixing.

7.  Read the Optical Density (O.D.) at 450 nm using a microtiter plate reader within 15 minutes.

 

CALCULATION OF RESULTS

1.         This standard curve is used to determine the amount in an unknown sample. The standard curve is generated by plotting the average O.D. (450 nm) obtained for each of the six standard concentrations on the vertical (X) axis versus the corresponding concentration on the horizontal (Y) axis.

2.         First, calculate the mean O.D. value for each standard and sample. All O.D. Values are subtracted by the mean value of the balnk well before result interpretation. Construct the standard curve using graph paper or statistical software.

3.         To determine the amount in each sample, first locate the O.D. value on the Y-axis and extend a horizontal line to the standard curve. At the point of intersection, draw a vertical line to the X-axis and read the corresponding concentration.

4.         Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in result. Each user should obtain their own standard curve.

5.         Intra-assay CV(%) and Inter-assay CV(%)are less than 15%.

6.         Assay range: 1.25μg/mL –40μg/mL.

7.  Sensitivity: The minimum detectable dose of Mouse IgG is typically less than 1.0μg/mL.

8.  Cross-reactivity: This assay recognizes recombinant and natural Mouse IgG. No significant cross-reactivity or interference was observed.

9.  Storage: 2-8℃ (Use frequently); six months (-20℃)。

10.  Standard curve

 

 

FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH ENTIRE PROCEDURE BEFORE BEGINNING!

 

 
 
[ 資料搜索 ]  [ ]  [ 告訴好友 ]  [ 打印本文 ]  [ 關(guān)閉窗口 ]  [ 返回頂部 ]

下載地址
 
  • 會(huì)員指數(shù):
  • 企業(yè)認(rèn)證:         
  • 聯(lián)系人:陳云云(女士)    
  • 地區(qū):上海
推薦資料
本類下載排行
總下載排行
精品国模一区二区三区,一区二区三区无码精油的作用,中文字幕亚洲欧美日韩在线不卡 ,日韩人妻一区二区三区蜜桃视频

            熟妇人妻一区二区| 秋霞av亚洲一区二区三| 亚洲精品国产精品国产| 97久久综合亚洲色HEZYO| 被强壮的公的侵犯伦理| 18一20亚洲gay无套| 中文字幕我被夫上司侵犯| 精品久久久久久久| 国产av在线播| 91免费看片下载| JZZIJZZIJ亚洲乱熟无码| 国产欧美日韩一区二区三区在线| 久久婷婷综合国产精品| 亚洲av日韩av欧av国内| 午夜国产精品一区二区| 欧美精品 在线观看| 久久国产精品久久| 国产日产一区二区| 国产成人自拍一区| 性中国少妇videofreesexwww| eeuss影院www免费快| 国产露脸对白刺激2022| 欧洲一区二区三区精品| 亚洲 欧美 叧类人妖| 99热在线这里只有精品| 午夜免费看片| 91熟女乱老熟女成熟| 人人妻人人爽人人添| 午夜在线视频| 一级黄片免费在线观看| 国产又粗又爽的视频| 国产精品扒开腿做爽爽的免费软件| 97人妻碰碰碰碰碰久久久久久 | 亚洲午夜精品久久久| 99在线精品免费视频| 久久久福利视频| 亚洲精品中文字幕| 免费一区二区欧美在线视频| av超碰在线| 欧美精品电影一区二区| 日韩av不卡一区二区|